An RH2000 series bench top capillary rheometer is capable of most testing requirements encountered in capillary rheometry
Rosand capillary rheometers

You are here:HomeLaboratory productsRheometersRosand capillary rheometersRH2000

RH2000 Capillary Rheometer

RH2000 rheometers are capable of most testing requirements encountered in capillary rheometry.
RH2000 capillary rheometers are capable of most testing requirements encountered in capillary rheometry.

The RH2000 Series - RH2100 & RH2200

Advanced bench-top, capillary rheometers suitable for research, product development and quality control.

The RH2000 series of bench top capillary rheometers are compact systems capable of most testing requirements encountered in capillary rheometry. The series is available in both single bore or twin bore configurations in the form of the RH2100 and the RH2200. Both versions of Rosand's bench top rheometer incorporate many of the features and attributes found in the floor standing models. A new digital drive system, gives the RH2000 series unsurpassed performance in terms of speed control, accuracy, and dynamic operating range. This new hardware is supported by the latest generation of 32 bit Windows™ based software, Flowmaster™, with many new experimental possibilities.

 

 

What's Next?



   
 
Capillary Rheometer AccessoriesCapillary Rheometer Datasheet

 

RH2000 Series
Drive Force :

12kN (standard)

  20kN (option)

Frame Stiffness:

  100kN

Drive Speed Maximum:

  600mm/min (standard)
    1,200mm/min (option)

Dynamic Speed Range:

 

200,000:1

(400,000:1 with high speed option)

Temperature Range:

  Ambient to 400°C, 500°C option.

    Low temperature cooling coil Option. Min temperature 10°C.

    Low temperature liquid Nitrogeb Option. Min temperature -40°C.

Bore Diameter:

  15 mm Standard, 9.5, 2, 19 & 24 mm bore options

Barrel Bore Length:

  250mm

Barrel Material:

  Standard Nitrided Steel, Hastelloy or Stainless Steel options.

Pressure Transducer Ranges (PSI):

  30,000, 20,000, 10,000, 5,000, 1,500, 500

Pressure Transducer Accuracy:

  Better than 0.5%

Dies:

  Tungsten Carbide, precision +/- 5 micron

Die Diameter:

  0.5 to 3mm Standard, other diameters available to special order

Software analysis functions:

  Calculation of non-Newtonian Index

    Calculation of Bagley Correction by Orifice Die and Extrapolation Methods

    Calculation of Rabinowitsch Corrections

    Hagenbach Correction for fluid inertia

    Cogswell Convergent Flow Model/Extensional Flow Assessment

    Extensive Plot and Print Options

    Data Export

Optional Software Module:

  Melt Fracture/Flow Instability Test Software

    Wall Slip Analysis Software

    Material Degradation/Thermal Stability Test Software

    Low Speed Degradation Test Software

    ETA-0 Analysis Software

    Stress Relaxation Test and Analysis Software


Laser Die Swell Options

 

 

RH2100
RH2200
Single Axis Laser Die Swell:

  Resolution 10 microns

 
Single Axis Twin Extrudate Laser Die Swell:

  Resolution 10 microns

   


Die & Melt Cutters

 
Die cutter:

  Die to cut distance : 0mm

Die to Sensor distance (strand length) : 85mm

Recommended maximum shear rate : 1000 s-1

 
Melt Cutter Single Strand:

  Die to cut distance : 100 to 160 mm

Die to Sensor distance (strand length) : 150 to 210 mm (50 mm below cut)

Recommended maximum shear rate : 1000 s-1

 
Melt Cutter Twin Strand:

  Die to cut distance : 100 to 160 mm

Die to Sensor distance (strand length) : 150 to 210 mm (50 mm below cut)

Recommended maximum shear rate : 1000 s-1

   


Hardware Accessories

 
Slot Die assembly:

  Slot Height 0.5 to 2.5 mm

 
PVT (Pressure, Volume Temperature) System

 

 
Nitrogen purge

     



Email a colleague about our particle characterization and rheology resources