Malvern's advanced, powerful floor standing capillary rheometry units are suitable for research and product development.
The RH7 & RH10 set new standards in research level capillary rheometry Malvern's floor standing capillary rheometry units are suitable for research and product development
Malvern's floor standing capillary rheometry units are suitable for research and product development Rosand capillary rheometers

You are here:HomeLaboratory productsRheometersCapillary rheometryRH7 and RH10

Capillary Rheometry Units RH7 and RH10

The RH7 & RH10 set new standards in research level capillary rheometry Malvern's floor standing capillary rheometry units are suitable for research and product development
The RH7  & RH10  set new standards in research level capillary rheometry.
The RH7  & RH10  set new standards in research level capillary rheometry.
An introduction to Capillary Rheometry
An introduction to Capillary Rheometry

Advanced, powerful floor standing capillary rheometry units suitable for research and product development.

Since its launch, the Rosand RH7 has set new standards in research level capillary rheometry. Today, the Rosand RH7 is used in several hundred research laboratories around the world for a range of rheometry applications including polymers, foods, coatings and ceramics.

Malvern has continuously developed the original RH7 design and its operating software to produce a new generation of floor standing capillary rheometry units with market leading performance characteristics and capabilities. The RH7 and RH10 rheometry units retain much of the robust 'H' frame design principle, which lies at the heart of the instruments' ability to operate under high loading conditions. A new digital drive system, gives the RH7 and the RH10 unsurpassed rheometry performance in terms of speed control, accuracy, and dynamic operating range. This new rheometry hardware is supported by the latest generation of 32 bit Windows™ based software, Flowmaster™, with many new experimental possibilities.

 

 

What's Next?



   
 
Rheometry AccessoriesRheometry Datasheet

 

RH7
RH10
Drive Force :

50kN

RH7 Capillary Rheometry Unit    
  100kN

    RH10 Capillary Rheometry Unit
Frame Stiffness:

  250kN

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Drive Speed Maximum:

  600mm/min
RH7 Capillary Rheometry Unit    
    1,200mm/min

    RH10 Capillary Rheometry Unit
Dynamic Speed Range:

  400,000:1

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Temperature Range:

  Ambient to 400ºC, 500ºC Option, twin bore barrel

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
    Low temperature cooling coil Option. Min temperature 10ºC, twin bore

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
    Low temperature liquid Nitrogeb Option. Min temperature -40ºC, single or twin bore.

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Bore Diameter:

  15 mm Standard, 9.5, 2, 19 & 24 mm bore options

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Barrel Bore Length:

  280mm

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Barrel Material:

  Standard Nitrided Steel, Hastelloy or Stainless Steel options.

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Pressure Transducer Ranges (PSI):

  30,000, 20,000, 10,000, 5,000, 1,500, 500

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Pressure Transducer Accuracy:

  Better than 0.5%

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Dies:

  Tungsten Carbide, precision +/- 5 micron

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Die Diameter:

  0.5 to 3mm Standard, other diameters available to special order

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Software analysis functions:

  Calculation of non-Newtonian Index RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
    Calculation of Bagley Correction by Orifice Die and Extrapolation Methods

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
    Calculation of Rabinowitsch Corrections

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
    Hagenbach Correction for fluid inertia

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
    Cogswell Convergent Flow Model/Extensional Flow Assessment

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
    Extensive Plot and Print Options

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
    Data Export

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Optional Software Module:

  Melt Fracture/Flow Instability Test Software

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
    Wall Slip Analysis Software

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
    Material Degradation/Thermal Stability Test Software

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
    Low Speed Degradation Test Software

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
    ETA-0 Analysis Software

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
    Stress Relaxation Test and Analysis Software

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit

 

Laser Die Swell Options

     
Single Axis Laser Die Swell:

  Resolution 10 microns

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Single Axis Twin Extrudate Laser Die Swell:

  Resolution 10 microns

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Dual Axis Laser Die Swell:

  Resolution 10 microns

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Single Axis High Resolution Laser Die Swell:

  Resolution 1 micron

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Dual Axis High Resolution Laser Die Swell:   Resolution 1 micron


RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit

 

Die & Melt Cutters

     
Melt Cutter Single Strand:

  Die to cut distance : 100 to 160 mm

Die to Sensor distance (strand length) : 150 to 210 mm (50 mm below cut)

Recommended maximum shear rate : 1000 s-1

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Melt Cutter Twin Strand:

  Die to cut distance : 100 to 160 mm

Die to Sensor distance (strand length) : 150 to 210 mm (50 mm below cut)

Recommended maximum shear rate : 1000 s-1

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit

 

Hardware Accessories

     
Slot Die assembly:

  Slot Height 0.5 to 2.5 mm

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
PVT (Pressure, Volume Temperature) System

 

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Haul Off/Melt Strength System:

 

Haul off motor/nip roller speed range : 2000 m/min max

Dynamic speed range > 100,000:1

Precision balance 2N capacity, 0.0001N resolution

Haul off die dimensions - 2.0mm (D) x 20mm (L) x 180° (Entrance angle)

RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit
Nitrogen purge

    RH7 Capillary Rheometry Unit   RH10 Capillary Rheometry Unit



Email a colleague about our capillary rheometry resources