The Insitec S particle size analyzer is designed to measure liquid droplets such as sprays and aerosols
Insitec S range

You are here:HomeProcess productsLaser diffractionSystemsInsitec S

Insitec S

Malvern's Insitec S provides users with real-time, high-speed particle size characteriztion measurement of high concentration liquid droplets such as sprays and aerosols.

 

Broad measuring range
Measures droplets from 0.1µm to 1000µm.

  High Speed Data Acquisition.
Real time spray measurement at up to 4 measurements per second, reveals fine temporal fluctuations in spray patterns.

  High concentration measurement capability.
Patented "multiple scattering" analysis routine allows measurements of sprays with light obscurations up to 95% (5% transmission).

 

User-friendly Software.
Time history display allows "frame by frame" inspection of a spray event. Flexible data filtering options. Compliance with 21 CFR Part 11.

 

Instrument Configuration Flexibility.
Customizable specification enables aerosol and spray researchers to configure an instrument to meet their precise needs.

 

Fit for purpose.
Purgeable optics to minimize spray contamination. Separate control and electronics unit gives robustness of operation in machinery areas.

 

Validation.
IQ/OQ available as per GAMP guidelines.

 

Applications.
Spray dryingapplications, atomizer characterization and development, climate studies, domestic aerosols, personal products.

The Insitec S particle size analyzer is designed for high speed droplet size measurements in concentrated sprays and aerosols

 

What's Next?



 

Insitec S datasheet

Specification

Droplet Size Range

Lens Focal Length
 

Maximum Working Distance.

0.1µm to 200µm

100 mm
 
150 mm

1.0µm to 400µm

200 mm
 
300 mm

2.25µm to 1000µm


450 mm
 
675 mm
Measurement principle:

  Mie scattering (Laser diffraction).
 
Light Source:
  Laser Diode 670 nm wavelength
 
Available Laser beam diameters:  

10 mm
6 mm
3 mm 1/e2
 

Measurement Rate:

  1 to 4 Hz.
Concentration Range:

  Sprays with obscurations from 2% to 95%.
 
Accuracy:   3% (using RS-3 reference standard reticle).
 
Precision:   0.5% (using RS-3 reference standard reticle).
 
Air Purge:   Optics can be purged with clean air to protect them from contamination during measurement. A minimum supply of 2ft³ min. is required - this air must be completely oil and water free.
 
Sealing Standards:

  Basic, IP65(Protected against dust / water jets. European standard).
 
Minimum Specification of PC:   Pentium II 300 MHz processor, 32 Mb RAM, 3Gbyte hard disc and CD–ROM.
Screen resolution VGA 800x600 (SVGA 1024x768 is recommended)
Requires 1 free serial port.
 
Operating System:

  Windows 2000
 
Data Analysis:   Model-independent analysis gives droplet size distribution Patented Multiple Scattering Algorithm for operation at high concentrations (US Patent No. 5,619,324).
Statistical analysis for QA/QC.
 
Data Display:   User configurable SPC charting and report formats.
 
Time History Display:

  "Frame-by-frame" data display.
 
Data Export:   Direct to Excel or similar spreadsheet.
 
Module Weights:   Transmitter module 5.75 kg.
Receiver module 7.50 kg.
 
Bench Options:   Short Bench - 300 mm spray gap. Height of laser above bench 250 mm

Long Bench - 500 mm spray gap. Height of laser above bench 250 mm

Custom Benches are available at extra cost depending on material, finish and size.