Skip to left navigation

Skip to page content

Follow us on... Facebook Twitter Materials Talks Blog YouTube Linked In

The Zetasizer Nano S is a research grade dynamic light scattering system for sub-micron particle and molecular size and molecular weight measurement that combines performance and versatility with exceptional ease of use. The system can be upgraded to add zeta potential capability at a later date.

Overview

The Zetasizer Nano S is the system of choice where the highest sensitivity and widest size range is required. It has the same sizing capability as the top of the range Zetasizer Nano ZS.

It is a particle size analyzer for the enhanced detection of aggregates, measurement of small or dilute samples, or samples at high concentration, plus a molecular weight analyzer for molecular size and molecular weight measurement.

Static light scattering measurements enable determination of the second virial coefficient for macromolecule solubility tests.

  • Size measurement from 0.3nm (diameter) to 10 microns using patented NIBS (Non-Invasive Back Scatter) technology.
  • Molecular weight measurement down to 980Da.
  • Second virial coefficient measurement for solubility.
  • Automated temperature trend measurements.
  • Sample concentrations from 0.1ppm to 40%w/v.
  • Protein size measurement as dilute as 0.1mg/mL (Lysozyme).
  • A Quality Factor gives confidence in the data.
  • The Expert advice report gives help to improve sample preparation or the measurement procedure.
  • 21CFR part 11 software option enables compliance with ER/ES.
  • Research software option gives access to further features and analysis algorithms for the light scattering specialist.
  • Automation of measurements using an autotitrator option.
  • Flow mode capability to enable use as a GPC / SEC detector.
  • Alternative laser, 50mW at 532nm for samples incompatible with the standard 633nm laser fitted.
  • Optical filter option to improve measurements with fluorescent sample.
  • Temperature range extension option to 120ēC.
  • Systems can be upgraded to add zeta potential at a later date.

Back

How it works

The Zetasizer Nano S incorporates 2 techniques in a single compact unit, and has a range of options and accessories to optimize and simplify the measurement of different sample types.

Dynamic Light Scattering is used to measure particle size and molecule size. This technique measures the diffusion of particles moving under Brownian motion, and converts this to size and a size distribution using the Stokes-Einstein relationship. Non-Invasive Back Scatter technology (NIBS) is incorporated to give the highest sensitivity simultaneously with the highest dynamic size and concentration range.

Static Light Scattering is used to determine the molecular weight of proteins and polymers. In this technique, the scattering intensity of a number of concentrations of the sample is measured, and used to construct a Debye plot. From this the average molecular weight and second virial coefficient can be calculated.
This measurement is very demanding on the sensitivity and stability of the whole system, and means that every element of the design has been optimised to ensure accuracy and repeatability

Software
The software is designed to be versatile and rich in features without compromising ease of use. Standard Operating Procedures (SOP) simplify routine measurements, a quality factor gives a single place to look for the success of a measurement, and expert advice is given to assist with data interpretation.

Options
The MPT-2 Autotitrator enables the study the effect of changes in pH, conductivity, or any additive to be automated.
A range of disposable and reusable cells are available to optimise the measurement in terms of sample volume, concentration and for flow measurement.

Other options include filters to improve the measurement of fluorescent samples, a temperature range extension to 120ºC and a viscometer to determine the sample viscosity to the accuracy required for the techniques used.

Back

Specification

Particle size and molecular size

Parameter

Specification

Measurement range:
0.3nm – 10.0 microns* (diameter)
Measurement principle:
Dynamic Light Scattering
Minimum sample volume:
12µL
Accuracy:
Better than +/-2% on NIST traceable latex standards
Precision/Repeatability
Better than +/-2% on NIST traceable latex standards

Molecular weight

Parameter

Specification

Measurement range:
980Da – 20M Da*
Measurement principle:
Static Light Scattering using Debye plot
Minimum sample volume:
12µL (3-5 sample concentrations required)
Accuracy:
+/- 10% typical
Precision/Repeatability
Better than +/-2% on NIST traceable latex standards
Patents granted:
NIBS
EP 0 884 580, DE 19725211, US 6016195, JP 2911877
Temperature control range:
0ºC - 90ºC +/-0.1**, 120ºC option
Light Source:
He-Ne laser 633nm, Max 5mW
Laser safety:
Class 1
Power: (V, Hz, VA)
100VA

Weight and dimensions:

Parameter

Specification

Dimensions (W, D, H)
320mm, 600mm, 260mm (W,D,H)
Weight: (kg)
21

Operating environment:

Parameter

Specification

Temperature:
15°C – 40°C
Humidity:
35% - 80% non-condensing

Software:

Parameter

Specification

Operating platforms:
Windows XP, VISTA, Windows 7
(compatible only with 32 bit versions of
Windows XP Pro and Windows 7)

Back

Accessories

A range of accessories are available to make life easier, or to add capability to the system

MPT-2 Autotitrator img

Automates experiments to study the effect of a change in sample conditions such as pH, conductivity, or the concentration of an additive. Up to three titrants can be used to increase and decrease pH for example.

See the MPT-2 Autotitrator
SV-10 viscometer img

An extremely simple and fast method of measuring the viscosity required for molecular size and zeta potential measurements. In 15 seconds the viscosity of 10mL of sample or dispersant can determined to an accuracy of 1% of samples with as low a viscosity as water. Water jacket supplied for temperature control (Note: Water bath required and available at additional cost)

See the SV-10 viscometer

Factory fitted options


50mW 532nm DPSS laser

For use where the sample is incompatible with the standard 633nm laser, either because the sample absorbs or fluoresces, or the sample is photosensitive.

The addition of this option does not affect the system specifications

Narrow band filters

Useful where the sample fluoresces. Will select the scattering from non-fluorescing particles and improve the signal to background ratio

High temperature capability

Increases the high temperature capability from 90ºC to 120ºC. Suitable for samples in wax media that melt above 90ºC


Back

 
 
Request a quote Contact us
 

Free registration

Access application notes, webinars, videos and more.

Register now