Viscotek 270max
A complete, temperature controlled, affordable RI, Viscometer and Light Scattering, triple-detector GPC/SEC system
The Viscotek 270max is a complete, column temperature controlled, multi-detector GPC/SEC system suitable for the routine characterization of proteins, natural and synthetic polymers, copolymers and other macromolecules.
Overview
The 270max consists of a selection of modules – the GPCmax integrated solvent and sample delivery module, Light Scattering and Viscosity module, RI detector and column oven, plus the same powerful OmniSEC software used in the TDAmax research system.
- Absolute molecular weight of small polymers, protein stability and protein aggregation using Right angle light scattering (RALS)
- Autosampler incorporated to increase throughput and improve repeatability
- Column oven to give repeatable elution profiles
- Direct output of absolute molecular weight of polymers without extrapolation using Low angle light scattering (LALS)
- Protein and polymer structure information using intrinsic viscosity detector for all sample and solvent types
- Molecular size in terms of hydrodynamic diameter and Rg
- Copolymer composition using single or multi-wavelength UV detector options
- Comprehensive functionality software featuring ‘two clicks from data to results’
- 3D absorption plot for chemical identification of each component
- 21 CFR part 11 compliant.
How it works
Gel Permeation Chromatography (GPC), also known as Size Exclusion Chromatography (SEC)
This is a chromatographic technique that employs specialized columns to separate natural and synthetic polymers, biopolymers, proteins on the basis of size.
As the sample is separated and elutes from the column, it can be characterized by a single concentration detector, using ‘Conventional calibration’, to give a relative molecular weight, the addition of viscosity enables the use of ‘Universal calibration’ to give true molecular weight and structural information, and ‘Triple Detection’, which adds light scattering to eliminate column calibration to give absolute molecular weight and distribution.
The 270max includes an integrated autosampler and pump, a triple detector and column oven.
A single or multiple wavelength UV detector can be added to provide compositional analysis for copolymer analysis or peak identification.
Specification
A complete GPC/SEC system including Conventional, Universal, Light Scattering, Triple, Copolymer, Protein specific, and FIPA calculation modules
Output of Mn, Mw, Mz, Mp, Mw/Mn, IV [η], Rh, Rg, Branching Number, Branching Frequency, Weight Fraction, Concentration, MH-a, MH-k, dn/dc, dA/dc. A2
- System
- GPCmax:
- Pump flow rate:
- 0.01 to 9.99 mL/min, programmable soft start
- Pulsation:
- Less than 1%, measured with viscometer
- Degasser:
- Two channels, < 0.5ppm oxygen at 0.5mL/min, eluent
sensor to stop pump when eluent runs out - Dimensions:
- 55cm x 53cm x 38cm (W x D x H)
- Weight:
- 37kg
- Autosampler
- Capacity:
- 120 vials, programmable sequence
- Injection volume:
- Variable 20 to 150µL
- Reproducibility:
- Better than 0.5%
- Carryover:
- Less than 0.1%, depending on wash program
- Cooling option:
- 4°C to 40°C, limited to 60 vials
- Heated tray option
- Up to 65°C limited to 60 vials heated, 60 vials unheated
- 270 Dual detector
- The detector can house both Light Scattering and
Viscometer technologies - Dimensions:
- 20cm x 47cm x 25cm (W x D x H)
- Weight
- 9.8Kg
- Detector 1:
- The light scattering detector has two independent
measurement angles. Low Angle 7° (LALS) and
Right Angle 90° (RALS) to provide absolute molecular
weight measurement without correction or extrapolation. - Interface:
- 6 channel digital to OmniSEC software,
2 analogue inputs RI and UV/LS - Light source:
- Laser diode, 3mW, 670nm
- Cell volume:
- 18µL
- Data rate:
- 5Hz to OmniSEC
- Detector 2:
- The differential viscometer provides a direct measurement
of intrinsic viscosity to enable determination of molecular
size, conformation and structure - Measurement principle:
- 4 capillary differential Wheatstone bridge configuration
- Transducers:
- Analogue, magnetic reluctance
- Cell volume:
- 18µL
- Purging:
- Manual via front panel ports
- Data rate:
- 5Hz to OmniSEC
- Detector 3:
- Refractive index
- Measurement principle:
- Deflection
- Light source:
- Tungsten lamp
- Cell volume:
- 9µL
- Purging:
- Manual, Automatic and programmable
- Data rate:
- 5Hz to OmniSEC
- Temperature control:
- 35° - 55°C in 1°C steps – normal environment
10° - 30°C in 1°C steps – cold room environment - Dimensions:
- 22cm x 35cm x 16cm (W x D x H)
- Weight
- 12Kg
- Column Oven
- Temperature control:
- 10°C above ambient to 100°C
- Capacity:
- Up to five 8mm x 30cm GPC columns
- Internal dimensions:
- 7cm x 41cm x 4cm (W x D x H)
- Detector 4 (option):
- UV, Single wavelength programmable
- Wavelength:
- 190 to 740nm
- Light source
- Deuterium, Tungsten halogen optional
- Cell volume:
- 10µL
- Data rate:
- Analog, A-to-D with 5Hz to OmniSEC
- Dimensions:
- 23cm x 39cm x 14cm (W x D x H)
- Weight:
- 6kg
- Detector 5 (option):
- UV-PDA
- Wavelength:
- 190 to 500nm or 710nm on 256 diode array
- Light source
- Deuterium (190 – 500nm), Tungsten halogen (430 – 710nm)
- Cell volume:
- 10µL
- Data rate:
- 256 channels with 1Hz to OmniSEC
- Laser safety:
- Class 1
- Operating environment:
- Temperature:
- 15°C – 40°C
- Humidity:
- 35% - 80% non-condensing
- Software:
- OmniSEC, 6 channels at 5Hz, unlimited acquisition time
- Minimum computer specification:
- 100 GB HD, 2GB RAM, 1.8 GHz processor,
Graphics 1024x768, 16-bit color depth - Operating platforms:
- Windows XP or higher
Accessories
Malvern - Viscotek accessories include all the components to meet the requirements of your application
Support
When you purchase a Malvern product we understand that this is just the first stage of a working relationship that will last for the lifetime of the instrument. Some customers just need to ask an occasional question or to download a software upgrade, whilst others require a comprehensive support contract with priority call out and fixed cost of ownership. Whatever your situation Malvern will provide the right support for you.
Help Desk
- Telephone and email support.
- Operators who take responsibility for your call and ensure your query is answered.
Training
- On Site training courses
- Classroom training
- e-formation
Resource Centre
- Application notes
- Technical notes
- On demand presentations
- Live webinars
Téléchargement de logiciel
- A simple mechanism for receiving updates and new features
Platinum and Gold Service Contracts:
- Protection from the cost of downtime
- No time lost in obtaining help when you need it
- Fixed cost of ownership
Bronze Service Agreements:
- Protect the value of your investment
- Reduce the risk of downtime
- Protect the validity of your data